Venting a DAFI Before First Start — a tiny move that saves the heating element
A dry heating element shows no mercy. One short burst of “air heating,” and the coil gets stressed for no reason. In DAFI instantaneous heaters, heating kicks in the moment flow is detected, so the only thing standing between a happy first start and a burnt element is a one-minute venting ritual. The rule is simple: before you feed it electricity, run water through the heating block until there isn’t a single bubble left inside. Let it flow for about a minute, then connect power. If there’s ever been a water outage, do it again before switching the power back on. That single minute saves money, time, and nerves.
DAFI’s manuals hammer the sequence home: water first, power second. Vent, wait for a steady, even stream without “coughing” air, then and only then touch the electrics. It’s not overkill. It’s the baseline for safe operation baked into the official startup steps. Make it a habit and you’ll never think about it again—except when you’re quietly pleased that everything just… works.
-
Water heater DAFI 7.5 kW 400 V (biphase)...
Water heater DAFI 7.5 kW 400 V (biphase) without monobloc (heating system only) Dafi water heater suitable for shower and sink / shower together. Unlike other water heaters, installing the DAFI water heater at any angle does not adversely impact its performance, and it does not damage the heating element.
94,99 €In Stock -
Dafi water heater 11 kW 400 V - under sink...
Small biphase Dafi Water Heater 11 kW 400 V with pipe connector ½ ".Dafi water heater suitable for bath and sink / tub combinations. Unlike other water heaters, installing the DAFI water heater at any angle does not adversely impact its performance, and it does not damage the heating element.
109,99 €In Stock -
Dafi water heater 7,5 kW 400 V - under...
Small biphase Dafi Water Heater 7.5 kW 400 V with pipe connector ½ ". Dafi water heater suitable for shower and sink / shower together. Unlike other water heaters, installing the DAFI water heater at any angle does not adversely impact its performance, and it does not damage the heating element.
99,99 €In Stock
How to vent a DAFI step by step — the one minute that does all the heavy lifting
Start on the water side. If you’ve got an isolating valve upstream, fit it, crack it open, and let a little water run to flush grit and air from the line before you hook up the heater. Make sure the cold inlet hits the stub marked “cold” (there’s an arrow on the back of the unit) — tiny detail, massive difference. Now open the hot side (or the “hot” knob on a DAFI tap) and let water flow until the hissing, spluttering and uneven stream disappear. Stick to the “about one minute of flow” rule before you ever think about turning on the power — it’s the simplest insurance policy you’ll ever own.
Using a DAFI mixer tap? Same story: open hot, vent thoroughly, then power. Installing “on a connection” under any regular tap? Still the same: water must pass through the heating block first, so the flow switch never “sees” a dry chamber. Then power. This order isn’t a nice-to-have; it’s the core of a smooth start. Once you’ve felt the difference — no scary noises, no weird temperature spikes — you’ll never skip it.
-
Dafi water heater 4,5 kW 230 V - over sink...
Small single-phase Dafi Water Heater 4.5 kW 230 V with plastic tap set. Suitable for sinks and washbasins in the bathroom. Water heater can be installed only with the supplied battery and spout.
79,99 €In Stock -
Water heater DAFI 4.5 kW 230 V (single...
Small single-phase Dafi Water Heater 4.5 kW 230 V with chromium-colored plastic monobloc. Suitable for sinks and washbasins in the bathroom. Water heater can be installed only with the supplied battery and spout.
94,99 €In Stock -
Water heater DAFI 4.5 kW 230 V (single...
Water heater DAFI 4.5 kW 230 V (single phase) with metal monobloc 180 mm Suitable for sinks and washbasins in the bathroom. Water heater can be installed only with the supplied battery and spout.
124,99 €Out of stock
First start after a water outage, remodel, or transport
Water cut off? Renovation in the riser? Moved the heater to a new spot? Do a “water reset.” Power off first. Open hot and let water run through the block for about a minute, watching for a clean, even stream with zero air. The same drill applies after any situation that might have left an air pocket in the unit — not a formality, a real safety net for your element. Only after that minute of calm flow do you switch power back on.
If, during day-to-day use, the unit suddenly spits air or the stream goes choppy, the plan doesn’t change: close water, power off, vent again, then restore power. No shortcuts. DAFI has almost no thermal inertia — it heats right now when water flows. That’s brilliant for comfort and bills, but it’s exactly why the venting ritual is sacred. In return, you get a stable start, a smooth stream, and zero drama in the first seconds of operation.
-
DAFI tap body with valves and 3/8" valve...
Original DAFI system component for a DAFI instantaneous water heater. Chrome-coloured plastic tap body with valves. Set includes 1 tap body and 2 valve heads 3/8" with seals.
10,99 €In Stock -
DAFI tap with 180 mm spout and aerator –...
Original DAFI system component: plastic tap in chrome colour with a 180 mm spout and aerator. Hot water is on the left. Threads: water inlet 1/2", heater connections M18x2 and spout connection M22x1,5.
24,99 €In Stock -
“Dafi Komfort” valve - chromium-colored
KOMFORT valve for Dafi flow water heaters. You don’t need to use the monobloc control knob! It is assembled between the monobloc and the spout. It is an original product by Formaster, the manufacturer of the heater.
8,69 €Out of stock
The usual first-start mistakes and how to dodge them (tell-tale symptoms to act on fast)
Mistake number one: powering up without venting. The symptoms? Little clicks and pops, a choppy stream, and in a worst-case scenario a damaged element. Number two: installing the unit where temps dip below freezing (ice inside means trouble) or — surprisingly common — mounting it inside a shower enclosure (nope, don’t do that; mind the protection zones and IP ratings). The manuals are crystal clear about this.
Pressure is another trap. DAFI is built for typical mains pressure. If your supply spikes high (especially above 0.6 MPa / 6 bar), add a pressure reducer — more comfort, less wear. Too little pressure, on the other hand, leads to start/stop behavior, a thin stream and the feeling the heater “doesn’t engage.” That’s straight out of the troubleshooting section. Stabilize the supply and you stabilize the heater.
And the classic: a gunked-up aerator or inlet screen. If the water swings too hot at a tiny flow, or the stream obviously drops, first descaling step is almost laughably simple: “flick” the rubber nubs on the aerator to knock limescale off, then rinse the inlet screen (you’ll find it on the hot side stub). That 60-second service move fixes more “mystery problems” than any phone call.
-
Heating element cover gasket for DAFI IPX4...
Original DAFI spare part for DAFI IPX4 under-sink instantaneous water heaters with a white 9-11 kW heating element. Plastic gasket used to seal the heating element cover after coil replacement. Supplied as 1 piece.
2,00 €In Stock -
Heating coil with gaskets for DAFI IPX4...
Original DAFI spare part for DAFI IPX4 under-sink instantaneous water heaters. Metal heating coil for the heating element. Power selectable in the offer. Set includes 1 coil and 2 gaskets.
6,99 €In Stock -
Brass reducing nipple DAFI M18x2 / 3/8"...
Original DAFI system component for DAFI water heaters. Brass reducing nipple with two male threads: M18x2 for the DAFI water heater and 3/8" for a flexible hose. Supplied as 1 piece.
3,69 €In Stock
Venting, pressure, filter, and aerator — four tiny habits that make a huge difference
First, vent before power. Always. Second, keep pressure in the “healthy” band. In practice that means fitting a reducer if your mains regularly climb over ~0.6 MPa (6 bar), and avoiding long dips below the minimum flow/pressure needed to trigger the flow switch. If your building has slam-happy flush valves or a jerky hydrofor, a reducer and flow stabilization will feel like a spa day for your heater.
Third, add a mechanical filter upstream. Less grit and sand equals cleaner channels, calmer starts, and a longer life for the element. Fourth, the aerator: that tiny tip on the spout doesn’t just make the stream feel nicer — its cleanliness affects the actual flow through the heating block, and that sets both temperature and the stability of the flow switch. A periodic “click-clean” of the rubber aerator nubs takes a second and often “heals” water behavior without touching the plumbing.
-
DAFI aerator reducer M22x1 M24x1, plastic
Original DAFI system component for DAFI aerator connections. Plastic reducer with M22x1 and M24x1 external threads. Supplied as 1 piece.
0,69 €In Stock -
White DAFI tap body with valve heads 3/8"...
Original DAFI system component: white plastic tap body for a DAFI instantaneous water heater. Hot water is on the left. Connections: water inlet 1/2", heater outlet M18x2 and valve heads 3/8". Set includes 1 body and 2 valve heads with seals.
9,99 €In Stock -
Upper housing for DAFI IPX5 over-sink...
Original DAFI spare part for the DAFI IPX5 over-sink water heater. Plastic upper housing forming the upper external part of the appliance. Supplied as 1 piece.
3,75 €In Stock
60-second checklist: the ritual before every power-on (and after every water outage)
- Isolating valve before the heater — open.
- Hot side — fully open.
- Let water run for about one minute; watch the stream. It should be steady, bubble-free, and quiet.
- If you’re finishing an installation, close hot; if you’re about to use the heater right away, leave it open.
- Only now switch electrical power on.
- During use, if you hear “spitting” or see air in the stream, shut water, power off, go back to step 2 and vent again; then restore power.
This is exactly what the manufacturer expects “before every power connection” and after outages. Simple, fast, effective.
Bonus tip: in “lively” systems (multi-family buildings, offices), don’t underestimate a pressure reducer. And remember that significant voltage drops on the electrical side reduce heating performance — sometimes that’s all that’s behind a “weak start” impression. A periodic rinse of the inlet screen and a quick aerator clean are minute-long jobs that keep temperature and flow in line for months.