One DAFI for a washbasin and a kitchen sink can only be considered after checking the exact model, its permitted plumbing arrangement and how both taps will be used. If the outlets are far apart or need to run together with a comfortable flow, compare two separate heaters. The number of taps alone is not enough to make the choice.

Start with three questions: is the chosen kit suitable for the proposed arrangement, how much hot water is needed at any one time, and how far must it travel? This guide helps you organise that information, compare situations and prepare specific questions for the installer before buying.

1. A permitted connection and comfortable use are different questions

The DAFI instructions describe supplying one or several draw-off points while also recommending a heater at each point. The section on installation with a connector specifies an IPX4 version and particular equipment. This does not allow two taps to be connected in any arrangement you choose.

First identify the exact kit and its instructions. The installer should confirm that the taps, connections and operating conditions are compatible. Then assess performance: an acceptable arrangement does not automatically provide the flow you expect for washing dishes and hands at the same time.

Do not transfer the possibilities of an undersink version to a kit with its own tap. The DAFI IPX5 listings checked require the supplied tap and spout. They are not a basis for designing a branch to any two taps. See the DAFI instructions and the guide to water connections according to the model documentation for an explanation of the fittings and arrangements.

Original photograph of the DAFI IPX4 3.7 kW 230 V kit with connector and valveExample of a specific IPX4 3.7 kW, 230 V kit. The listing photograph is not a diagram for an installation serving two outlets.

2. Two taps used one after the other

Imagine a small flat where one person washes their hands in the bathroom and then rinses a cup in the kitchen. Only one flow is needed at a time. This places different demands on the heater from two taps running together.

A shared appliance can then be assessed against the more demanding task, provided the whole arrangement is permitted. Check, however, whether using the taps in sequence reflects the occupants’ actual habits. With two people at home, overlapping demand can easily be an everyday occurrence.

For a few days, note typical situations: breakfast, the morning bathroom routine, cleaning and visitors. Saying that the basin is rarely used is less useful than knowing whether someone opens its tap while dishes are being washed. The choice should suit how you want to use your home, without constantly agreeing who may turn on the water.

The same applies in the back room of a small shop. One person might use the basin only before starting work, while another washes their hands frequently, including during cleaning at the sink. The number of stations and the floor area are the same, but demand follows a different pattern. Establish whether using the taps in sequence is a convenient habit or a restriction the new heater would introduce.

Comparison of washbasin and sink use, one after the other in the first example and overlapping in the secondIllustration of how the taps are used. It does not show how to connect the appliances.

3. What changes when both taps run together?

With two taps open, consider their combined demand. For example, two hot-water flows of 2 l/min add up to 4 l/min. This illustrates adding flow rates, not a declaration that the chosen DAFI will provide that amount at the temperature you expect.

Always read performance figures with their test conditions. The shop’s DAFI IPX4 4.5 kW, 230 V listing gives 2.4 l/min with water entering at 15°C, leaving at 40°C and a pressure of 0.2 MPa. That figure is for the whole heater, not 2.4 l/min separately at each of two taps.

This comparison helps reveal a mismatch between expectations and the listing data early on. Flow distribution, mixing with cold water and pressure changes also depend on the installation. Opening the second tap can change conditions at the first. Do not assume either a fixed half-and-half split or an unchanged temperature.

You can describe your needs more precisely by measuring the flow at an existing tap that works correctly. Measure the volume collected over a set time: half a litre in 15 seconds equals 2 l/min. Note the tap setting and water temperature, since measuring the cold flow alone does not describe hot-water demand. Do not alter connections or commission an unapproved two-outlet arrangement for this test.

If you want independent use of the kitchen and bathroom, compare two local heaters or another solution with confirmed capabilities. The DAFI power selection guide helps you assess a single appliance. A higher power rating also means checking the available electrical supply.

4. Measure the pipe run, not the distance between doors

A basin and sink may be on opposite sides of the same wall, yet their pipes take a longer route. Elsewhere, rooms close together on the plan may be linked by several metres of pipework. Have the actual pipe length and internal diameter established.

After a break in use, water left in the pipe may have cooled. That section must be flushed through before warmer water reaches the tap. A heater starting quickly does not therefore mean instant hot water at a distant basin.

Geometric example for a pipe with a 10 mm internal diameter
Pipe lengthWater in the pipeFlushing at 2 l/min
2 mabout 0.16 labout 5 s
5 mabout 0.39 labout 12 s
10 mabout 0.79 labout 24 s

This calculates the pipe volume and the time to replace its contents at a constant flow. It excludes warming the pipe, heat loss, mixing and heater operation. It is not a prediction of waiting time in your installation. It simply shows why pipe length and diameter matter.

There is no single distance here beyond which you must always buy a second heater. Consider how often water is drawn and what waiting time is acceptable. The article on hot water at a distant sink explains how to take useful measurements.

5. Allow for colder incoming water in winter

Assess performance for the conditions in which the appliance must work throughout the year. If incoming water is colder in winter, achieving the same outlet temperature at a given power requires a lower flow. A kit sufficient for a quick summer rinse may not meet expectations when washing dishes in winter.

Define the basin’s and sink’s needs separately. Handwashing, rinsing vegetables and removing grease from dishes for longer periods involve different durations and expected flows. Give the installer a description of the tasks and incoming-water data, rather than just asking how many kilowatts two taps need.

6. When should you compare one heater with two?

The table below helps organise the decision. Every option requires an arrangement permitted for the exact model and an assessment of the installation.

SituationWhat to compare
Nearby outlets genuinely used in sequenceAssess one appliance, the more demanding task and the water route.
Both taps regularly used togetherTwo local heaters or another source with confirmed combined capacity.
Distant outlets with frequent short drawsCompare separate heaters at the taps with the cost and waiting time of a shared arrangement.
The chosen kit does not permit the proposed splitChange the concept or choose separate kits, without modifying the heater.

The need for two units can therefore arise from the kit design, the independence you want or insufficient performance from a shared solution. Having two taps alone does not settle the issue. First compare the options against the same needs.

7. Choose a complete kit for each station

Among undersink versions, you can compare the DAFI IPX4 3.7 kW, 230 V and DAFI IPX4 4.5 kW, 230 V, offered with a DAFI connector and valve. These are examples to assess for a specific station, not a ready-made selection for supplying two taps.

Check the listing contents, required equipment and whether you can retain the current tap. A heating element alone and a complete installation kit are different purchases. The guide to DAFI capabilities and limitations also explains design and equipment differences.

For separate stations, an above-basin solution can also be assessed. The DAFI IPX5 3.7 and 4.5 kW, 230 V listings include a white tap, spout and aerator. These kits use the supplied tap and spout, as in the DAFI IPX5 4.5 kW, 230 V. You are choosing the whole station, not merely changing the heater casing.

8. Two units require an assessment of the whole electrical supply

A heater at each tap separates hot-water production, but does not remove electrical requirements. If both operate together, their combined demand must be considered alongside the other electrical appliances in the premises.

For example, nominal ratings of 3.7 and 4.5 kW add up to 8.2 kW. This does not confirm suitability for your incoming supply, circuits or protection devices. Have an electrician assess them. The list of installation details needed before buying DAFI will help you prepare.

Compare full costs too: heaters, taps, plumbing and electrical work, then operation. Two units do not automatically double the bill for heating the water. Power drawn and actual heating time matter. Use the electricity consumption and cost calculator with your own assumptions, calculating each heater separately.

Ask for a quotation separating purchase costs from preparing the services at each station. For two nearby points, a second electrical supply may be a significant cost; for distant ones, altering pipework for a shared heater may matter more. Do not decide before you know both scopes of work.

9. What should you prepare for selection?

Before sending an enquiry, put together a short description:

  • the two stations and tasks carried out at each,
  • how often water is drawn and when both taps are used together,
  • the required temperature and a flow measured or agreed with a professional,
  • the actual pipe route, photographs of the taps and available space,
  • the chosen model’s details and electrical supply capabilities checked by an electrician.

Request confirmation of a specific proposal: one permitted arrangement or two suitably selected kits, with an explanation of expected comfort and a full quotation. You can then compare ways of meeting the same need, rather than just the prices of two product listings.

Frequently asked questions

Will one DAFI always be enough for a basin and sink?

The number of taps alone cannot establish this. Confirm the model’s permitted arrangement, performance, pattern of use and the water route to both outlets.

Will two separate DAFI heaters allow independent use?

Each can serve its own suitably assessed station. The required plumbing and electrical conditions must still be provided during simultaneous operation. A second unit does not automatically overcome the limits of a shared supply.

Will a more powerful model solve the long-pipe problem?

More power does not remove water left in the pipe after a pause. For a distant tap, consider the pipe route and the possibility of preparing hot water locally as well.

Do two smaller DAFI units work like one larger heater?

Their ratings are added when assessing electrical demand, but each has its own output and station. Unused power at the basin does not increase the sink heater’s performance. Each outlet must be assessed for its own tasks.

Can one DAFI instantaneous water heater supply a kitchen sink and a shower?

Consider one DAFI if the model’s manual allows the setup and an installer confirms it can deliver the required flow and temperature at both outlets. When you use the sink and shower separately, the heater serves one outlet at a time. If someone turns on the kitchen hot tap during a shower, the heater must handle the combined flow. At the same power, a higher flow means a smaller temperature rise. Start with the shower’s needs and allow for colder incoming water in winter. See the DAFI winter shower guide for examples of flow rates and temperatures.

When should you consider two separate water heaters?

Consider separate heaters if the pipe run between the kitchen and bathroom is long or you often use both outlets together. Water left in the pipe cools between uses and comes out first. A heater closer to the outlet can shorten the wait. Size each heater for its own task. Check the flow you need for washing up and the flow and temperature you need for showering. Before buying, have an installer assess the water supply at both outlets and ask an electrician to check the circuits and total load when both heaters and other appliances run together.

The best choice fits everyday use of both stations. Start with a permitted arrangement, compare sequential and simultaneous use, then check performance, distance and supply. Only that information allows you to decide whether one heater or two separate units suit your situation.